BXCQ Explosion Proof Overflow Static Grounding Control System Flameproof Type

BXCQ Explosion Proof Overflow Static Grounding Control System Flameproof Type
Download Download Brochure
Data
BXCQ-YJC Explosion-proof Overflow Static Grounding Controller Ex II 2 G Ex db ia IIB+H2 T6 Gb
Ex II 2 D Ex ia tb IIIC T80℃ Db
Protection degree: IP66
Response time: <1S
Test resistance: <10Ω
Working voltage: 100~250V AC 50/60HZ,220V~240V AC 50/60Hz, 24V DC
Working current: <20mA
Working current: <20mA
Warning method: Interlocking signal and three color light instruction
Output signal: Relay output, NO NC is optional, 10A 30VDC or 10A 250VAC
Enclosure size: 200x300x170 mm
Installation dimension: 210x230 mm
BXCQ-JC Explosion-proof StaticGrounding Controller Ex II 2 G Ex db ia IIB+H2 T6 Gb
Ex II 2 D Ex ia tb IIIC T80℃ Db IP66
Protection degree: IP66
Response time: <1S
Test resistance: <10Ω
Working voltage: 100~250V AC 50/60HZ, 220V~240V AC 50/60Hz, 24V DC
Working current: lt20mA
Warning method: sound and light alarm (optional)
Output signal: Relay output, NO NC is optional, 10A 30VDC or 10A 250VAC
Enclosure size: 200x300x170 mm
Installation dimension: 210x230 mm
BXCQ-YC Explosion-proof Overflow Controller Ex II 2 G Ex db ia IIB+H2 T6 Gb
II 2 D Ex tb IIIC T80℃ Db IP66
Working voltage: 100~250V AC 50/60HZ,220V~240V AC 50/60Hz, 24V DC
Working current: <20mA
Warning method: Interlocking signal and three  color light instruction
Output signal: Relay output, NO NC is optional 10A 30VDC or 10A 250VAC
Enclosure size: 200x300x170 mm
Installation dimension: 210x230 mm
BXCQ-JCL Explosion-proof Static  Grounding Controller (dual purposes of manand motor) Ex II 2 G Ex db ia IIB T6 Gb
Ex II 2 D Ex  ia tb IIIC T80℃ Db IP66
Protection degree: IP66
Response time: lt1S >
Test resistance: lt 10Ω
Working voltage: 220VAC or 24VDC
Warning method: sound and light alarm (optional)
Output signal: Relay output, NO NC is optional,  10A 30VDC or 10A 250VAC
Touching ball material: Electrostatic subconductor
Touching ball diameter: 90mm
Enclosure size: 200x300x170 mm
Installation dimension: 210x230 mm
BXJ-IIB  Series Explosion-proof  Junction Box Ex II 2 G Ex db IIB+H2 T6 Gb
Ex II 2 D Ex tb IIIC T80℃ Db IP66
Protection degree: IP66
Static Grounding Clamp Clamp tooth material: Tungsten alloy
Opening range:Clamp body material: 304 (316 optional)
Corrosion Resistance Helical Line Cable material: Copper wire
Surface material: PU
Standard equipment length: 7m
Homing board Material: 304 stainless steel
warromLogo
Engineering Diagram
Specification
The controller enclosure is flameproof type, reliable explosion-proof performance.
Static grounding clamp has tank car identification function, ensure its installed on tank car correctly, not other electric conductor, with no-spark type grounding clamp, no spark produced when equipment impact.
Grounding body resistance has inspection function, ensure reliable grounding of system, when electrostatic grounding is bad or grounding loop resistance >10Ω, provide alarm warning.
With voice and LCD function, the intensity of the sound is 70~120db (the distance is 30cm).
Relay signal output for DCS pump (valve), when grounding is not normal, cut off the operation, audible and visual alarm can still be remote controlled, remind operator the real-time status of on-site grounding.
Red LED shows warning, green LED shows normal working, yellow LED shows standby status.
Grounding clamp uses alloy aiding thimble, with the features of high hardness, good electric conduction, strong breaking paint and rust power, etc. ensure good grounding monitoring device.
Grounding clamp is helix tube shrink design, with the capacities of strength anti-pull, anti-drop, etc.
It can intelligently detect whether the human static voltage is conducted, when the human static voltage is in a dangerous value,sound and light alarm.